Power Generation

Turbine oil filtration and varnish removal for power plants

We fit CJC depth filtration to turbine lube circuits, EHC fluids, transformer oil and standby diesel, on load.

Turbine hall of a power plant

What goes wrong

Varnish and soft deposits

Oxidation products settle on servo valves and coolers; particle counts miss them.

Water in the lube oil

Gland steam and condensation put water in, attacking additives and corroding surfaces.

Fine particles in control oil

The 3 to 5 µm silt passing inline filters is what seizes spools.

Transformer oil drift

Moisture rises between annual tests; the usual fix needs an outage.

The cost of an unplanned trip

An unplanned trip costs lost generation, not oil price. A varnish unit can also save a 30,000 litre charge from replacement.

The business case

What we fit

Sizing starts with the reservoir volume and the last MPC result.

filter_alt

Varnish removal unit

Removes oxidation products, verified by MPC testing before and after.

filter_alt

Fine filter on the tank

3 µm absolute depth filtration that also absorbs free and emulsified water.

filter_alt

Online transformer treatment

Permanently mounted filtration and drying, running with the transformer energised.

Products
Project Profile

Steam turbine lube system, 30,000 L

Slow valve response with normal particle counts, but MPC in alarm. A varnish unit cleared it in ten weeks; the oil stayed in service.

A typical project: customer not named, figures indicative. Verified site data available on request.

Case studies
Oil sample before filtration, dark and cloudy

Before

Oil sample after offline filtration, clear and bright

After

Common questions

Can you fit filtration without taking the turbine off load?

add

Yes. It connects to the reservoir, not the lube circuit, and runs while the unit runs.

Will filtration remove varnish that has already deposited?

add

It removes precursors from the oil, and deposits slowly dissolve out over weeks. Baked-on deposits may need mechanical cleaning.

Do you handle phosphate ester and fire resistant fluids?

add

Yes, with the correct insert grade. These fluids need different media from mineral turbine oil.

Technical Enquiry

Request a turbine oil assessment

Send particle count, water content and MPC if available. We will say whether it is varnish or particles.

  • We reply within one working day.
  • We size the unit for your tank and oil, not from a catalogue.

Sent over an encrypted connection. We use your details only to answer this enquiry.